Zeiss eXtended data
Zeiss lenses utilising the eXtended data protocol can be used with the Ncam system. As the eXtended protocol is an extension of the Cooke /i protocol the two methods share many similarities and the encoder cable provided by Ncam is interchangeable between the two.
Firmware Requirement
When using 2023.0 versions of Ncam Reality, the Zeiss XD lens must be using at least version 1.7.1. If using Ncam Reality 2023.1 and later, then earlier versions of XD firmware are supported
Ncam provided /i serial cable
Zeiss eXtended data lens featuring a 4 pin lemo connector
The eXtended data protocol is only available on the Mk2 platform
Inside the preferences of the Ncam Reality Full UI set the encoder type to "Zeiss eXtended data"
Connect the Ncam /i cable to the RS232 port of the Mk2 server or connection box, connect the 4 pin lemo end of the cable to the eXtended data port on the body of the lens